LoRaWAN M-Bus and Modbus RTU Converters
M-Bus → LoRaWAN

IC200-MBUS-LW
M-Bus · LoRaWAN · EU868
Ordering Options
IC200-MBUS-LW.EU.0.1.1.0
Internal antenna
Battery included / not included
Battery included / not included
IC200-MBUS-LW.EU.1.1.1.0
Internal + external antenna
Battery included / not included
Battery included / not included
Modbus RTU → LoRaWAN

IC200-MRTU-LW
Modbus RTU / RS-485 · LoRaWAN · EU868
Ordering Options
IC200-MRTU-LW.EU.0.1.1.0
Internal antenna
Battery included / not included
Battery included / not included
IC200-MRTU-LW.EU.1.1.1.0
Internal + external antenna
Battery included / not included
Battery included / not included
Best suited for
Remote reading of heat, water, electricity and energy meters with M-Bus communication via LoRaWAN
Integration of Modbus RTU / RS-485 devices, meters, sensors and field equipment into a LoRaWAN network
Field protocol
M-Bus
Modbus RTU / RS-485
Connectable devices
10 M-Bus slaves
10 Modbus RTU slaves
Field connection
1 × M-Bus port
1 × RS-485 port
Pulse / Digital input
1 channel
Pulse or digital status
Pulse or digital status
1 channel
Pulse or digital status
Pulse or digital status
Input signal
Dry contact / Open Collector
Dry contact / Open Collector
Max. pulse frequency
100 Hz
200 Hz with additional EMI protection
200 Hz with additional EMI protection
100 Hz
200 Hz with additional EMI protection
200 Hz with additional EMI protection
Digital output
1 × Open Collector
Max. 1 A · 24 VDC
Max. 1 A · 24 VDC
1 × Open Collector
Max. 1 A · 24 VDC
Max. 1 A · 24 VDC
LoRaWAN
LoRaWAN 1.0.4
Class A / Class C
EU868
Class A / Class C
EU868
LoRaWAN 1.0.4
Class A / Class C
EU868
Class A / Class C
EU868
LoRaWAN activation
ABP / OTAA
ABP / OTAA
Data transmission interval
1 / 5 / 10 / 30 minutes
1 / 4 / 6 / 12 / 24 hours
1 / 4 / 6 / 12 / 24 hours
5 / 15 / 30 minutes
1 / 4 / 6 / 12 / 24 hours
1 / 4 / 6 / 12 / 24 hours
Internal memory
8 MB Flash
20,000 data packets
20,000 data packets
8 MB Flash
20,000 data packets
20,000 data packets
Configuration
Bluetooth LE 5.1
akYtec IoT Configurator
akYtec IoT Configurator
Bluetooth LE 5.1
akYtec IoT Configurator
akYtec IoT Configurator
NFC
NFC-A activation / identification
NFC-A activation / identification
Data security
Hardware-based AES-128
Hardware-based AES-128
Antenna options
Internal
Internal + external antenna
Internal + external antenna
Internal
Internal + external antenna
Internal + external antenna
Battery / power supply
2 × CR123A · 3 V
3,000 mAh total
or 5…30 VDC
3,000 mAh total
or 5…30 VDC
2 × CR123A · 3 V
3,000 mAh total
or 5…30 VDC
3,000 mAh total
or 5…30 VDC
Estimated Battery Life
Up to 5 years
Up to 5 years
Protection rating
IP65
IP65
Operating temperature
−40…+70 °C
−40…+70 °C
Dimensions
129 × 79 × 29 mm
129 × 79 × 29 mm
Note: Battery life may vary depending on the LoRaWAN data transmission interval, connected field devices, communication activity and device configuration. LoRaWAN Class A mode can be used when operating on battery power, while Class C mode is available with an external DC power supply.
LORAWAN INFRASTRUCTURE
LoRaWAN Gateway
The RX LORAWAN gateway can be used to integrate LoRaWAN sensors, input modules or control devices into building management systems and to centrally monitor / control them via LoRaWAN. The gateway collects data from LoRaWAN nodes and transfers it to BMS or PLC systems via Modbus or BACnet.
LoRaWAN Gateway

RX LORAWAN
500-602 · EU868
500
LoRaWAN node connections
A scalable architecture that allows up to 500 LoRaWAN devices to be managed through a single gateway.
Embedded LoRaWAN Network Server
The LNS is integrated into the gateway, allowing a private LoRaWAN network to be deployed without requiring a separate external network server.
Enless + third-party LoRaWAN
Enless LoRaWAN products are decoded natively. Compatible third-party LoRaWAN devices can also be added to the system using JavaScript codecs and JSON mapping.
BMS / HVAC INTEGRATION
From LoRaWAN directly to building automation protocols
Modbus
TCP / RTU
BMS / PLC
BACnet
IP / MS/TP
BMS / HVAC
Power supply: 12–24 V AC/DC or PoE
Mounting: DIN rail or screw mounting
Configuration: Built-in web interface
Protection: IP60
Note: The RX LORAWAN Gateway can be used to integrate Enless Wireless LoRaWAN sensors and compatible third-party LoRaWAN devices into BMS or PLC systems via Modbus and BACnet.