Home Company Products Catalog Blog Contact 0216 364 02 10
NOVUS N1540 and N1500 Panelmeter Indicators - novus-panelmetre-gosterge.jpg

NOVUS N1540 and N1500 Panelmeter Indicators

What Are the NOVUS N1500 and N1540 Process Indicators?

The NOVUS N1500 and N1540 are universal panel indicators designed to display temperature and standard analog process signals. With different panel sizes, alarm outputs and Modbus communication options, they can be adapted to a wide range of measurement and monitoring applications.

Process Indicator Models N1540-AO N1540-485 N1500
Product Images

Dimensions
  • 48 x 96 mm (horizontal)
  • Depth: 35 mm
  • Panel Cutout Dimensions: 45.5 x 93 mm
  • 48 x 96 mm (horizontal)
  • Depth: 35 mm
  • Panel Cutout Dimensions: 45.5 x 93 mm
  • 48 x 96 mm (horizontal)
  • Depth: 92 mm
  • Panel Cutout Dimensions: 45 x 93 mm
Input Types
  • Pt100, Thermocouple Temperature Sensors
  • 0-20 mA, 4-20 mA, 0-50 mV, 0-5 VDC, 0-10 VDC
  • Non-Linear 4-20 mA
  • Pt100, Thermocouple Temperature Sensors
  • 0-20 mA, 4-20 mA, 0-50 mV, 0-5 VDC, 0-10 VDC
  • Non-Linear 4-20 mA
  • Pt100, Thermocouple Temperature Sensors
  • 0-20 mA, 4-20 mA, 0-50 mV, 0-5 VDC, 0-10 VDC
  • Non-Linear 4-20 mA, 0-20 mA, 0-5 VDC, 0-10 VDC
Functions
  • 10-Point Correction Factor Input (Linearization for 4-20 mA)
  • Offset Input
  • Filter Input (Digital Filter)
  • USB Port for Easy PC Configuration (Free Software)
  • Various Alarm Functions
  • 10-Point Correction Factor Input (Linearization for 4-20 mA)
  • Offset Input
  • Filter Input (Digital Filter)
  • USB Port for Easy PC Configuration (Free Software)
  • Various Alarm Functions
  • 30-Point Correction Factor Input (Linearization for 4-20 mA)
  • Offset Input
  • Filter Input (Digital Filter)
  • USB Port for Easy PC Configuration (Free Software)
  • Various Alarm Functions
Output 1 Relay Relay Relay
Output 2 Relay Relay Relay
Output 3 4-20 mA RS-485 Modbus Relay
Output 4 - - Relay
Output 5 - - 4-20 mA
Output 6 - - RS-485 Modbus
Sensor Power Supply Output

Available

24 VDC
(20 mA)

Available

24 VDC
(20 mA)

Available

24 VDC
(25 mA)

Power Supply

100...240 VAC

100...240 VAC 100...240 VAC
Configuration

Easy configuration using the buttons on the device or via PC connection through the USB port with free software

Easy configuration using the buttons on the device or via PC connection through the USB port with free software Easy configuration using the buttons on the device or via PC connection through the USB port with free software
Process Indicator Wiring Diagram

novus-automation-n1500-kullanma-kilavuzu-3.jpg
Download
novus-automation-n1500-katalog-4.jpg
Download
novus-n1540-kullanma-kilavuzu-2.jpg
Download
novus-n1540-katalog-1.jpg
Download

What Outputs Are Available on the Process Indicators?

Our process indicators operate on 220 VAC, feature universal inputs, and support the connection of many different types of sensors. For sensors with 4-20 mA or 0-10 VDC outputs, the indicator can provide the required power directly through its 24 VDC sensor supply output, eliminating the need for an additional power supply.

  • The N1540-AO process indicator features one 4-20 mA output. In addition to displaying the measurement value, it can transmit the measurement signal to PLC systems via the 4-20 mA output. It also includes 2 relay outputs.
  • The N1540-485 process indicator features an RS-485 Modbus output. It also includes 2 relay outputs as standard.
  • The N1500 process indicator features both 4-20 mA and RS-485 Modbus outputs. It also includes 4 relay outputs.

All of our process indicators feature a USB port. In addition to configuration using the buttons on the device, all settings can be configured more easily from a computer using the free software.

Can Volume Linearization Be Configured for Irregularly Shaped Tanks When Connecting a Level Sensor to the Process Indicator?

Yes. The N1540 series process indicators support up to 10-point curve linearization, while the N1500 series process indicator supports up to 30 points. This allows you to accurately define the corresponding volume in liters or kilograms at different level points of an irregularly shaped tank or silo.

This feature can also be used for sensor error correction.

Do the N1540 and N1500 Process Indicators Have a Sensor Power Supply Output?

Yes, all of our process indicators feature a 24 VDC sensor power supply output. As you know, Pt100 and thermocouple temperature sensors can be connected directly, while sensors such as pressure transmitters, level sensors and flow meters require an external power supply. Our process indicators operate on 220 VAC and provide a 24 VDC output for powering these sensors. Therefore, no additional power supply is required for the sensor.

Demo software downloads will be activated by filling out the form.
Now you can download the following software suitable for you. After clicking the button, the download link of the software will be sent to your e-mail address.
WhatsApp
×
Demo of this product is available.