Ana Sayfa Kurumsal Ürünler Katalog Blog İletişim 0216 364 02 10
RHT Climate DM Duct-Mount Humidity & Temperature Transmitter - rht-climate-dm.webp

RHT Climate DM Duct-Mount Humidity & Temperature Transmitter

What Is the RHT Climate Duct-Mounted Humidity & Temperature Transmitter?

The RHT Climate DM is a transmitter with a stainless steel probe, designed to measure humidity and temperature in ventilation ducts. With high-accuracy humidity measurement, different probe length options, analog outputs, digital alarm outputs and Modbus communication, it can be easily integrated into HVAC, BMS and climate control systems.

Models RHT Climate-DM-LCD-150 RHT Climate-DM-LCD-250 RHT Climate-DM-LCD-400
Product Images
Probe Length 150 mm 250 mm 400 mm
Models RHT Climate-DM-150 RHT Climate-DM-250 RHT Climate-DM-400
Product Images
Probe Length 150 mm 250 mm 400 mm
Measurement Range 0-100 %RH 0-100 %RH 0-100 %RH
Humidity Accuracy ±1.8 %RH ±1.8 %RH ±1.8 %RH
       
Temperature Measurement Range -40...+100 ºC -40...+100 ºC -40...+100 ºC
Temperature Accuracy ±0.2 ºC ±0.2 ºC ±0.2 ºC
Operating Temperature

-40...+100 ºC (probe)

-40...+60 ºC (electronics)

-40...+100 ºC (probe)

-40...+60 ºC (electronics)

-40...+100 ºC (probe)

-40...+60 ºC (electronics)

       
Output 1 4-20 mA or 0-10 VDC 4-20 mA or 0-10 VDC 4-20 mA or 0-10 VDC
Output 2 4-20 mA or 0-10 VDC 4-20 mA or 0-10 VDC 4-20 mA or 0-10 VDC
Outputs 3 and 4 DO (ON/OFF) DO (ON/OFF) DO (ON/OFF)
Output 5 RS-485 Modbus RS-485 Modbus RS-485 Modbus
       
Power Supply 12...30 VDC 12...30 VDC 12...30 VDC
       
Configuration - Settings USB Port
(via free PC software)
       
Calculated Parameters

Dew Point

Absolute Humidity

Wet-Bulb Temperature

Frost Point

 

(These calculated parameters can be assigned to the display or analog outputs. They can also be read via RS-485 Modbus together with temperature and relative humidity values.)

       
Protection Rating

Housing: IP65 Probe: IP30

Electronic Housing Dimensions

100 x 80 x 45 mm

       
Probe Length Options

150 mm

250 mm 400 mm

 

rht-climate-nem-kullanma-kilavuzu-2.jpg
Download
rht-climate-nem-katalog-1.jpg
Download

Does the Duct-Mounted Humidity Sensor Have an RS-485 Modbus Output?

The RHT Climate duct-mounted humidity sensor is available with an RS-485 Modbus output option. For the duct-mounted humidity transmitter, we generally keep the fully equipped version in stock, featuring 2 analog outputs, 2 digital ON/OFF outputs for alarm control, and an RS-485 Modbus output.

The duct-mounted humidity sensor is available in both display and non-display versions with 3 different probe length options: 150 mm, 250 mm and 400 mm.

Our company offers a wide range of humidity sensors and humidity transmitters. We can help you select the most suitable solution for your application and recommend the right humidity sensor product.

Can We Configure the Desired Scale for the Analog Outputs of the Duct-Mounted Humidity Sensor?

The analog outputs of the RHT Climate duct-mounted humidity sensor can be scaled as required. For example, you can configure the sensor so that the 4-20 mA output represents a range of 10-90% RH, or configure the 0-10 VDC output to represent a temperature range of 0-80 ºC.

What Is the Operating Temperature Range of the Probe for the Duct-Mounted Humidity Sensor?

The RHT Climate duct-mounted humidity sensor can operate between -40 and +100 ºC and can measure humidity within this temperature range. This is the operating temperature range of the humidity sensor probe. The operating temperature range of the electronic housing located outside the duct is -40...+60 ºC.

Demo software downloads will be activated by filling out the form.
Now you can download the following software suitable for you. After clicking the button, the download link of the software will be sent to your e-mail address.
WhatsApp
×
Demo of this product is available.

You can download the free demo to try this product. To access the download form click.